Abstract

Abstract

Prosthesis-patient mismatch (PPM) is present when the effective orifice area of the inserted prosthetic valve is too small in relation to body size. Its main hemodynamic consequence is to generate higher than expected gradients through normally functioning prosthetic valves. The purpose of this review is to present an update on the present state of knowledge with regards to diagnosis, prognosis and prevention of PPM. PPM is a frequent occurrence (20%–70% of aortic valve replacements) that has been shown to be associated with worse hemodynamics, less regression of left ventricular hypertrophy, more cardiac events, and lower survival. Moreover, as opposed to most other risk factors, PPM can largely be prevented by using a prospective strategy at the time of operation.

Loading

Article metrics loading...

/content/journals/10.5339/ahcsps.2011.7
2011-04-14
2019-08-18
Loading full text...

Full text loading...

/deliver/fulltext/ahcsps/2011/1/ahcsps.2011.7.html?itemId=/content/journals/10.5339/ahcsps.2011.7&mimeType=html&fmt=ahah

References

  1. [1]. Rahimtoola SH.. The problem of valve prosthesis-patient mismatch. . Circulation . 1978; ;58(1): : 20– 24 .
    [Google Scholar]
  2. [2]. Dumesnil JG., , Honos GN., , Lemieux M., and Beauchemin J.. Validation and applications of indexed aortic prosthetic valve areas calculated byDoppler echocardiography. . J Am Coll Cardiol . 1990; ;16(3): : 637– 643 .
    [Google Scholar]
  3. [3]. Dumesnil JG., and Yoganathan AP.. Valve prosthesis hemodynamics and the problem of high transprosthetic pressuregradients. . Eur J Cardio-thorac Surg . 1992; ;6(Suppl I): : S34– S38 .
    [Google Scholar]
  4. [4]. Dumesnil JG., , Honos GN., , Lemieux M., and Beauchemin J.. Validation and applications of mitral prosthetic valvular areas calculated byDoppler echocardiography. . Am J Cardiol . 1990; ;65(22): : 1443– 1448 .
    [Google Scholar]
  5. [5]. Muneretto C., , Bisleri G., , Negri A., and Manfredi J.. The Concept of Patient-Prosthesis Mismatch. . J Heart Valve Dis . 2004; ;13(Supplement1): : S59– S62 .
    [Google Scholar]
  6. [6]. Marquis C., , Meister JJ., , Mooser E., and Mosimann R.. Pulsed Doppler assessment of deep femoral artery hemodynamics: a preliminaryreport. . Angiology . 1984; ;35: : 269– 275 .
    [Google Scholar]
  7. [7]. Pibarot P., , Dumesnil JG., , Cartier PC., , Métras J., and Lemieux M.. Patient-prosthesis mismatch can be predicted at the time of operation. . Ann ThoracSurg . 2001 May; ;71(5 Suppl): : S265– S268 .
    [Google Scholar]
  8. [8]. Koch CG., , Khandwala F., , Estafanous FG., , Loop FD., and Blackstone EH.. Impact of prosthesis-patient size on functional recovery after aortic valvereplacement. . Circulation . 2005 June 21; ;111(24): : 3221– 3229 .
    [Google Scholar]
  9. [9]. Mohty D., , Malouf JF., , Girard SE., , Schaff HV., , Grill DE., , Enriquez-Sarano ME., and Miller FA Jr... Impact of prosthesis-patient mismatch on long-term survival in patients with smallSt. Jude medical mechanical prostheses in the aortic position. . Circulation . 2006 January 24; ;113(3): : 420– 426 .
    [Google Scholar]
  10. [10]. Bleiziffer S., , Eichinger WB., , Hettich I., , Guenzinger R., , Ruzicka D., , Bauernschmitt R., and Lange R.. Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement:which is the best method?. . Heart . 2007 May; ;93(5): : 615– 620 .
    [Google Scholar]
  11. [11]. Medalion B., , Blackstone EH., , Lytle BW., , White J., , Arnold JH., and Cosgrove DM.. Aortic valve replacement: Is valve size important?. . J Thorac Cardiovasc Surg . 2000; ;119: : 963– 974 .
    [Google Scholar]
  12. [12]. Blackstone EH., , Cosgrove DM., , Jamieson WR., , Birkmeyer NJ., , Lemmer JH Jr.., , Miller DC., , Butchart EG., , Rizzoli G., , Yacoub M., and Chai A.. Prosthesis size and long-term survival after aortic valve replacement. . J ThoracCardiovasc Surg . 2003 September; ;126(3): : 783– 793 .
    [Google Scholar]
  13. [13]. Fernandez J., , Chen C., , Laub GW., , Anderson WA., , Brdlik OB., , Murphy MM., and Mcgrath LB.. Predictive value of prosthetic valve area index for early and late clinical results aftervalve replacement with the St Jude Medical valve prosthesis. . Circulation . 1996; ;94(9Suppl): : II-109– II-112 .
    [Google Scholar]
  14. [14]. Howell NJ., , Keogh BE., , Barnet V., , Bonser RS., , Graham TR., , Rooney SJ., , Wilson IC., and Pagano D.. Patient-prosthesis mismatch does not affect survival following aortic valvereplacement. . Eur J Cardiothorac Surg . 2006 May 22; ;30(1): : 10– 14 .
    [Google Scholar]
  15. [15]. Monin JL. . Prosthesis-patient mismatch: myth or reality?. . Heart . 2009 June; ;95(11): : 948– 952 .
    [Google Scholar]
  16. [16]. Zoghbi WA., , Chambers JB., , Dumesnil JG., , Foster E., , Gottdiener JS., , Grayburn PA., , Khandheria BK., , Levine RA., , Marx GR., , Miller FA Jr.., , Nakatani S., , Quinones MA., , Rakowski H., , Rodriguez LL., , Swaminathan M., , Waggoner AD., , Weissman NJ., and Zabalgoitia M.. Recommendations for evaluation of prosthetic valves with echocardiography anddoppler ultrasound: a report From the American Society of Echocardiography’sGuidelines and Standards Committee and the Task Force on Prosthetic Valves,developed in conjunction with the American College of Cardiology CardiovascularImaging Committee, Cardiac Imaging Committee of the American Heart Association,the European Association of Echocardiography, a registered branch of theEuropean Society of Cardiology, the Japanese Society of Echocardiographyand the Canadian Society of Echocardiography, endorsed by the AmericanCollege of Cardiology Foundation, American Heart Association, EuropeanAssociation of Echocardiography, a registered branch of the European Society ofCardiology, the Japanese Society of Echocardiography, and Canadian Society ofEchocardiography. . J Am Soc Echocardiogr . 2009 September; ;22(9): : 975– 1014 .
    [Google Scholar]
  17. [17]. Pibarot P., and Dumesnil JG.. Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valveposition and its prevention. . J Am Coll Cardiol . 2000 October; ;36(4): : 1131– 1141 .
    [Google Scholar]
  18. [18]. Pibarot P., , Honos GN., , Durand LG., and Dumesnil JG.. The effect of prosthesis-patient mismatch on aortic bioprosthetic valve hemodynamicperformance and patient clinical status. . Can J Cardiol . 1996 April; ;12(4): : 379– 387 .
    [Google Scholar]
  19. [19]. Pibarot P., , Dumesnil JG., , Lemieux M., , Cartier P., , Metras J., and Durand LG.. Impact of prosthesis-patient mismatch on hemodynamic and symptomatic status,morbidity and mortality after aortic valve replacement with a bioprosthetic heartvalve. . J Heart Valve Dis . 1998 March; ;7(2): : 211– 218 .
    [Google Scholar]
  20. [20]. Yun KL., , Jamieson WRE., , Khonsari S., , Burr L.H., , Munro AI., and Sintek CF.. Prosthesis-patient mismatch: hemodynamic comparison of stented and stentlessaortic valves. . Semin Thorac Cardiovasc Surg . 1999; ;11(4 (Suppl.1)): : 98– 102 .
    [Google Scholar]
  21. [21]. Rao V., , Jamieson WRE., , Ivanov J., , Armstrong S., and David TE. . Prosthesis-patient mismatch affects survival following aortic valve replacement. . Circulation . 2000; ;102(Supp III): : III-5– III-9 .
    [Google Scholar]
  22. [22]. Milano AD., , De CM., , Mecozzi G., , D’alfonso A., , Scioti G., , Nardi C., and Bortolotti U.. Clinical outcome in patients with 19-mm and 21-mm St. Jude aortic prostheses:comparison at long-term follow-up. . Ann Thorac Surg . 2002 January; ;73(1): : 37– 43 .
    [Google Scholar]
  23. [23]. Hanayama N., , Christakis GT., , Mallidi HR., , Joyner CD., , Fremes SE., , Morgan CD., , Mitoff PR., and Goldman Bs.. Patient prosthesis mismatch is rare after aortic valve replacement: valve size may beirrelevant. . Ann Thorac Surg . 2002 June; ;73(6): : 1822– 1829 .
    [Google Scholar]
  24. [24]. Tasca G., , Brunelli F., , Cirillo M., , DallaTomba M., , Mhagna Z., , Troise G., and Quaini E. . Impact of valve prosthesis-patient mismatch on left ventricular mass regressionfollowing aortic valve replacement. . Ann Thorac Surg . 2005 February; ;79(2): : 505– 510 .
    [Google Scholar]
  25. [25]. Botzenhardt F., , Eichinger WB., , Guenzinger R., , Bleiziffer S., , Wagner I., , Bauernschmitt R., and Lange R.. Hemodynamic performance and incidence of patient-prosthesis mismatch of thecomplete supraannular perimount magna bioprosthesis in the aortic position. . ThoracCardiovasc Surg . 2005 August; ;53(4): : 226– 230 .
    [Google Scholar]
  26. [26]. Botzenhardt F., , Eichinger WB., , Bleiziffer S., , Guenzinger R., , Wagner IM., , Bauernschmitt R., and Lange R.. Hemodynamic comparison of bioprostheses for complete supra-annular position inpatients with small aortic annulus. . J Am Coll Cardiol . 2005 June 21; ;45(12): : 2054– 2060 .
    [Google Scholar]
  27. [27]. Kohsaka S., , Mohan S., , Virani S., , Lee VV., , Contreras A., , Reul GJ., and Coulter SA.. Prosthesis-patient mismatch affects long-term survival after mechanicalvalve replacement. . J Thorac Cardiovasc Surg . 2008 May; ;135(5): : 1076– 1080 .
    [Google Scholar]
  28. [28]. Mohty D., , Dumesnil JG., , Echahidi N., , Mathieu P., , Dagenais F., , Voisine P., and Pibarot P.. Impact of prosthesis-patient mismatch on long-term survival after aortic valvereplacement: influence of age, obesity, and left ventricular dysfunction. . J Am CollCardiol . 2009 January 6; ;53(1): : 39– 47 .
    [Google Scholar]
  29. [29]. Flameng W., , Herregods MC., , Vercalsteren M., , Herijgers P., , Bogaerts K., and Meuris B.. Prosthesis-patient mismatch predicts structural valve degeneration in bioprostheticheart valves. . Circulation . 2010 May 3; ;
    [Google Scholar]
  30. [30]. Blais C., , Dumesnil JG., , Baillot R., , Simard S., , Doyle D., and Pibarot P.. Impact of valve prosthesis-patient mismatch on short-term mortality after aorticvalve replacement. . Circulation . 2003 August 26; ;108(8): : 983– 988 .
    [Google Scholar]
  31. [31]. Tanne D., , Kadem L., , Rieu R., and Pibarot P.. Hemodynamic impact of mitral prosthesis-patient mismatch on pulmonaryhypertension: an in silico study. . J Appl Physiol . 2008 December; ;105(6): : 1916– 1926 .
    [Google Scholar]
  32. [32]. Li M., , Dumesnil JG., , Mathieu P., and Pibarot P.. Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure aftermitral valve replacement. . J Am Coll Cardiol . 2005 April 5; ;45(7): : 1034– 1040 .
    [Google Scholar]
  33. [33]. Mohan Reddy V., , McElhinney DB., , Phoon CK., , Brook MM., and Hanlon JG.. Geometric mismatch of pulmonary and aortic anuli in children undergoing the Rossprocedure: implications for surgical management and autograft valve function. . JThorac Cardiovasc Surg . 115: : 1255– 1263 .
    [Google Scholar]
  34. [34]. Magne J., , Mathieu P., , Dumesnil JG., , Tanné D., , Dagenais F., , Doyle D., and Pibarot P.. Impact of prosthesis-patient mismatch on survival after mitral valve replacement. . Circulation . 2007 March 20; ;115(11): : 1417– 1425 .
    [Google Scholar]
  35. [35]. Lam BK., , Chan V., , Hendry P., , Ruel M., , Masters R., , Bédard P., , Goldstein B., , Rubens F., and Mesana T.. The impact of patient-prosthesis mismatch on late outcomes after mitralvalve raplacement. . J Thorac Cardiovasc Surg . 2007 June; ;133(6): : 1464– 1473 .
    [Google Scholar]
  36. [36]. Jamieson WR., , Germann E., , Ye J., , Chan F., , Cheung A., , Macnab JS., , Fradet GJ., , Stanford EA., , Bryson LA., and Lichtenstein SV.. Effect of prosthesis-patient mismatch on long-term survival with mitral valvereplacement: assessment to 15 years. . Ann Thorac Surg . 2009 April; ;87(4): : 1135– 1141 .
    [Google Scholar]
  37. [37]. Aziz A., , Lawton JS., , Maniar HS., , Pasque MK., , Damiano RJ., and Moon Jr... Factors affecting survival after mitral valve replacement in patients withprosthesis-patient mismatch. . Ann Thorac Surg . 2010 October; ;90(4): : 1202– 1211 .
    [Google Scholar]
  38. [38]. Del Rizzo DF., , Abdoh A., , Cartier P., , Doty DB., and Westaby S.. Factors affecting left ventricular mass regression after aortic valve replacement withstentless valves. . Semin Thorac Cardiovasc Surg . 1999; ;11(4 (Suppl.1)): : 114– 120 .
    [Google Scholar]
  39. [39]. Freed DH., , Tam JW., , Moon MC., , Harding GE., , Ahmad E., and Pascoe EA.. Nineteen-millimeter prosthetic aortic valves allow normalization of left ventricularmass in elderly women. . Ann Thorac Surg . 2002 December; ;74(6): : 2022– 2025 .
    [Google Scholar]
  40. [40]. Tasca G., , Brunelli F., , Cirillo M., , Amaducci A., , Mhagna Z., , Troise G., and Quaini E.. Mass regression in aortic stenosis after valve replacement with small sizepericardial bioprosthesis. . Ann Thorac Surg . 2003 October; ;76(4): : 1107– 1113 .
    [Google Scholar]
  41. [41]. Knez I., , Rienmüller R., , Maier R., , Rehak P., , Schröttner B., , Mächler H., , Anelli-Monti M., and Rigler B.. Left ventricular architecture after valve replacement due to critical aortic stenosis:an approach to dis-/qualitfy the myth of valve prosthesis-patient mismatch?. . Eur JCardio-thorac Surg . 2001; ;19: : 797– 805 .
    [Google Scholar]
  42. [42]. Tasca G., , Brunelli F., , Cirillo M., , Dalla Tomba M., , Mhagna Z., , Troise G., and Quaini E.. Impact of the improvement of valve area achieved with aortic valve replacement onthe regression of left ventricular hypertrophy in patients with pure aortic stenosis. . Ann Thorac Surg . 2005 April; ;79(4): : 1291– 1296 .
    [Google Scholar]
  43. [43]. Dumesnil JG.. Invited commentary. . Ann Thorac Surg . 2005 April; ;79(4): : 1296
    [Google Scholar]
  44. [44]. Briand M., , Dumesnil JG., , Kadem L., , Tongue AG., , Rieu R., , Garcia D., and Pibarot P.. Reduced systemic arterial compliance impacts significantly on left ventricularafterload and function in aortic stenosis: Implications for diagnosis and treatment. . JAm Coll Cardiol . 2005 July 19; ;46(2): : 291– 298 .
    [Google Scholar]
  45. [45]. Pagé A., , Dumesnil JG., , Clavel MA., , Chan KL., , Teo K., , Tam JW., , Mathieu P., , Després JP., and Pibarot P.. Metabolic syndrome is associated with more pronounced impairment of LVgeometry and function in patients with calcific aortic stenosis: A substudy of theASTRONOMER trial. (Aortic Stenosis Progression Observation MeasuringEffects of Rosuvastatin). . J Am Coll Cardiol . 20100 April 27; ;55(17): : 1867– 1874 .
    [Google Scholar]
  46. [46]. Weidemann F., , Herrmann S., , Stork S., , Niemann M., , Frantz S., , Lange V., , Beer M., , Gattenlohner S., , Voelker W., , Ertl G., and Strotmann JM.. Impact of myocardial fibrosis in patients with symptomatic severe aortic stenosis. . Circulation . 2009 August 3; ;120(7): : 577– 584 .
    [Google Scholar]
  47. [47]. Dumesnil JG., , Shoucri RM., , Laurenceau JL., and Turcot J.. A mathematical model of the dynamic geometry of the intact left ventricle and itsapplication to clinical data. . Circulation . 1979; ;59(5): : 1024– 1034 .
    [Google Scholar]
  48. [48]. Pibarot P., and Dumesnil JG.. Longitudinal myocardial shortening in aortic stenosis: Ready for prime time after 30years of research?. . Heart . 2009 January; ;96(2): : 95– 96 .
    [Google Scholar]
  49. [49]. Hachicha Z., , Dumesnil JG., , Bogaty P., and Pibarot P.. Paradoxical low flow low gradient severe aortic stenosis despite preserved ejectionfraction is associated with higher afterload and reduced survival. . Circulation . 2007 June 5; ;115(22): : 2856– 2864 .
    [Google Scholar]
  50. [50]. Hachicha Z., , Dumesnil JG., and Pibarot P.. Usefulness of the valvuloarterial impedance to predict adverse outcome inasymptomatic aortic stenosis. . J Am Coll Cardiol . 2009 September 8; ;54(11): : 1003– 1011 .
    [Google Scholar]
  51. [51]. Bergler-Klein J., , Mundigler G., , Pibarot P., , Burwash IG., , Dumesnil JG., , Blais C., , Beanlands R., , Hachicha Z., , Mohty D., , Fuchs C., , Loho N., , Florian R., and Baumgartner H.. B-type natriuretic peptide in low-flow, low-gradient aortic stenosis: relationship tohemodynamics and clinical outcome. . Circulation . 2007 June 5; ;115(22): : 22 , 2848– 2855 .
    [Google Scholar]
  52. [52]. Rajappan K., , Rimoldi O., , Camici PG., , Pennell DJ., and Sheridan DJ.. Factors influencing coronary microcirculatory function in patients withaortic stenosis after aortic valve replacement. . Circulation . 2002; ;106(19): : II-640
    [Google Scholar]
  53. [53]. Rajappan K., , Rimoldi OE., , Camici PG., , Bellenger NG., , Pennell DJ., and Sheridan DJ.. Functional changes in coronary microcirculation after valve replacementin patients with aortic stenosis. . Circulation . 2003 July 1; ;107(25): : 3170– 3175 .
    [Google Scholar]
  54. [54]. Garcia D., , Camici PG., , Durand LG., , Rajappan K., , Gaillard E., , Rimoldi OE., and Pibarot P.. Impairment of coronary flow reserve in aortic stenosis. . J Appl Physiol . 2009 January; ;106(1): : 113– 121 .
    [Google Scholar]
  55. [55]. Clavel MA., , Fuchs C., , Burwash IG., , Mundigler G., , Dumesnil JG., , Baumgartner H., , Bergler-Klein J., , Beanlands RS., , Mathieu P., , Magne J., and Pibarot P.. Predictors of outcomes in low-flow, low-gradient aortic stenosis: results of themulticenter TOPAS Study. . Circulation . 2008 September 30; ;118(14 Suppl): : S234– S242 .
    [Google Scholar]
  56. [56]. Clavel, MA, Webb, J, Rodés-Cabau, J, Masson, JB, Dumont, E, De Larochelliere, R, Doyle, D, Bergeron, S, Baumgartner, H, Burwash, I, Dumesnil, JG, Mundigler, G, Moss, R, Kempny, A, Bagur, R, Mathieu, P, Bergler-Klein, J and Pibarot, P,Comparison between surgical and transcatheter prosthetic valve implantation patients with severe aortic stenosis and reduced left ventricular ejection fraction.Circulation. In press 2010.
  57. [57]. Clavel MA., , Webb JG., , Pibarot P., , Altwegg L., , Dumont E., , Thompson C., , De Larochelliere R., , Doyle D., , Masson JB., , Bergeron S., , Bertrand OF., and Rodes-Cabau J.. Comparison of the hemodynamic performance of percutaneous and surgicalbioprostheses for the treatment of severe aortic stenosis. . J Am Coll Cardiol . 2009 May 19; ;53(20): : 1883– 1891 .
    [Google Scholar]
  58. [58]. Jilaihawi H., , Chin D., , Spyt T., , Jeilan M., , Vasa-Nicotera M., , Bence J., , Logtens E., and Kovac J.. Prosthesis-patient mismatch after transcatheter aortic valve implantationwith the Medtronic-Corevalve bioprosthesis. . Eur Heart J . 2009 December 25; ;
    [Google Scholar]
  59. [59]. Connolly HM., , Oh JK., , Schaff HV., , Roger VL., , Osborn SL., , Hodge DO., and Tajik AJ.. Severe aortic stenosis with low transvalvular gradient and severe left ventriculardysfunction. Result of aortic valve replacement in 52 patients. . Circulation . 2000; ;101: : 1940– 1946 .
    [Google Scholar]
  60. [60]. Walther T., , Rastan A., , Falk V., , Lehmann S., , Garbade J., , Funkat AK., , Mohr FW., and Gummert JF.. Patient prosthesis mismatch affects short- and long-term outcomes afteraortic valve replacement. . Eur J Cardiothorac Surg . 2006 May 24; ;30(1): : 15– 19 .
    [Google Scholar]
  61. [61]. Urso S., , Sadaba R., and Aldamiz-Echevarria G.. Is patient-prosthesis mismatch an independent risk factor for early and mid-termoverall mortality in adult patients undergoing aortic valve replacement?. . InteractCardiovasc Thorac Surg . 2009 September; ;9(3): : 510– 518 .
    [Google Scholar]
  62. [62]. Kulik A., , Burwash IG., , Kapila V., , Mesana TG., and Ruel M.. Long-term outcomes after valve replacement for low-gradient aortic stenosis: Impactof prosthesis-patient mismatch. . Circulation . 2006; ;114(Suppl 1): : I5553– I5558 .
    [Google Scholar]
  63. [63]. Ruel M., , Al-Faleh H., , Kulik A., , Chan K., , Mesana TG., and Burwash IG.. Prosthesis-patient mismatch after aortic valve replacement primarily affects patientswith pre-existing left ventricular dysfunction: Impact on survival, freedom fromheart failure, and left ventricular mass regression. . J Thorac Cardiovasc Surg . 2006 May; ;131(5): : 1036– 1044 .
    [Google Scholar]
  64. [64]. Bleiziffer S., , Ali A., , Hettich IM., , Akdere D., , Laubender RP., , Ruzicka D., , Boehm J., , Lange R., and Eichinger W.. Impact of the indexed effective orifice area on mid-term cardiac-relatedmortality after aortic valve replacement. . Heart . 2010 June; ;96(11): : 865– 871 .
    [Google Scholar]
  65. [65]. Tasca G., , Mhagna Z., , Perotti S., , Centurini PB., , Sabatini T., , Amaducci A., , Brunelli F., , Troise G., and Pibarot P.. Impact of prosthesis-patient mismatch on cardiac events and midterm mortalityafter aortic valve replacement in patients with pure aortic stenosis. . Circulation . 2006 January 31; ;113(4): : 570– 576 .
    [Google Scholar]
  66. [66]. Moon MR., , Pasque MK., , Munfakh NA., , Melby SJ., , Lawton JS., , Moazami N., , Codd JE., , Crabtree TD., , Barner HB., and Damiano RJ Jr.. Prosthesis-patient mismatch after aortic valve replacement: impact of age andbody size on late survival. . Ann Thorac Surg . 2006 February; ;81(2): : 481– 488 .
    [Google Scholar]
  67. [67]. Mihaljevic T., , Nowicki ER., , Rajeswaran J., , Blackstone EH., , Lagazzi L., , Thomas J., , Lytle BW., and Cosgrove DM.. Survival after valve replacement for aortic stenosis: implications for decisionmaking. . J Thorac Cardiovasc Surg . 2008 June; ;135(6): : 1270– 1278 .
    [Google Scholar]
  68. [68]. Ruel M., , Rubens FD., , Masters RG., , Pipe AL., , Bedard P., , Hendry PJ., , Lam BK., , Burwash IG., , Goldstein WG., , Brais MP., , Keon WJ., and Mesana TG.. Late incidence and predictors of persistent or recurrent heart failure in patientswith aortic prosthetic valves. . J Thorac Cardiovasc Surg . 2004 January; ;127(1): : 149– 159 .
    [Google Scholar]
  69. [69]. Mascherbauer J., , Rosenhek R., , Fuchs C., , Pernicka E., , Klaar U., , Scholten C., , Heger M., , Wollenek G., , Maurer G., and Baumgartner H. . Moderate patient-prosthesis mismatch after valve replacement for severe aorticstenosis has no impact on short- and long term mortality. . Heart . 2008 May 1; ;
    [Google Scholar]
  70. [70]. Monin JL., , Monchi M., , Kirsch ME., , Petit-Eisenmann H., , Baleynaud S., , Chauvel C., , Metz D., , Adams C., , Quere JP., , Gueret P., and Tribouilloy C.. Low-gradient aortic stenosis: impact of prosthesis-patient mismatch on survival. . EurHeart J . 2007 November; ;28(21): : 2620– 2626 .
    [Google Scholar]
  71. [71]. Howell NJ., , Keogh BE., , Ray D., , Bonser RS., , Graham TR., , Mascaro J., , Rooney SJ., , Wilson IC., and Pagano D.. Patient-prosthesis mismatch in patients with aortic stenosis undergoingisolated aortic valve replacement does not affect survival. . Ann Thorac Surg . 2010 January; ;89(1): : 60– 64 .
    [Google Scholar]
  72. [72]. Jamieson WR., , Ye J., , Higgins J., , Cheung A., , Fradet GJ., , Skarsgard P., , Germann E., , Chan F., and Lichtenstein SV.. Effect of prosthesis-patient mismatch on long-term survival with aortic valvereplacement: assessment to 15 years. . Ann Thorac Surg . 2010 January; ;89(1): : 51– 58 .
    [Google Scholar]
  73. [73]. Flameng W., , Meuris B., , Herijgers P., and Herregods MC.. Prosthesis-patient mismatch is not clinically relevant in aortic valvereplacement using the Carpentier-Edwards Perimount valve. . Ann Thorac Surg . 2006 August; ;82(2): : 530– 536 .
    [Google Scholar]
  74. [74]. Vicchio M., , De Feo M., and Cotrufo M.. Prosthesis-patient mismatch does not affect survival and quality of life inthe elderly having bileaflet prostheses implant. . J Thorac Cardiovasc Surg . 2009 September; ;138(3): : 787– 788 .
    [Google Scholar]
  75. [75]. Moon MR., , Lawton JS., , Moazami N., , Munfakh NA., , Pasque MK., and Damiano RJ Jr.. POINT: Prosthesis-patient mismatch does not affect survival for patients greaterthan 70 years of age undergoing bioprosthetic aortic valve replacement. . J ThoracCardiovasc Surg . 2009 February; ;137(2): : 278– 283 .
    [Google Scholar]
  76. [76]. Dumesnil JG., , Magne J., , Girerd N., and Pibarot P.. Moderate patient-prosthesis mismatch can impact on mortality after aortic valvereplacement. . Heart . 2009 April; ;95(7): : 592– 593 .
    [Google Scholar]
  77. [77]. Urso S., , Sadaba R., , Vives M., , Trujillo J., , Beltrame S., , Soriano B., , Piqueras L., and Aldamiz-Echevarria G.. Patient-prosthesis mismatch in elderly patients undergoing aortic valve replacement:impact on quality of life and survival. . J Heart Valve Dis . 2009 May; ;18(3): : 248– 255 .
    [Google Scholar]
  78. [78]. Ennker J., , Rosendahl U., , Albert A., , Dumlu E., , Ennker IC., and Florath I.. Stentless bioprostheses in small aortic roots: impact of patient-prosthesis mismatchon survival and quality of life. . J Heart Valve Dis . 2005 July; ;14(4): : 523– 530 .
    [Google Scholar]
  79. [79]. Bleiziffer S., , Eichinger WB., , Hettich I., , Ruzicka DJ., , Wottke M., , Bauernschmitt R., and Lange R.. Impact of prosthesis-patient mismatch on exercise capacity in patientsafter bioprosthetic aortic valve replacement. . Heart . 2008 May; ;94(5): : 637– 641 .
    [Google Scholar]
  80. [80]. Ruel M., , Rubens FD., , Masters RG., , Pipe AL., , Bedard P., and Mesana TG.. Late incidence and predictors of persistent or recurrent heart failure in patientswith mitral prosthetic valves. . J Thorac Cardiovasc Surg . 2004 August; ;128(2): : 278– 283 .
    [Google Scholar]
  81. [81]. Vincentelli A., , Susen S., , Le Tourneau T., , Six I., , Fabre O., , Juthier F., , Bauters A., , Decoene C., , Goudemand J., , Prat A., and Jude B.. Acquired von Willebrand syndrome in aortic stenosis. . N Engl J Med . 2003 July 24; ;349(4): : 343– 349 .
    [Google Scholar]
  82. [82]. Yoshida K., , Tobe S., , Kawata M., and Yamaguchi M.. Acquired and reversible von Willebrand disease with high shear stress aortic valvestenosis. . Ann Thorac Surg . 2006 February; ;81(2): : 490– 494 .
    [Google Scholar]
  83. [83]. Mannacio VA., , De AV., , Di Tommaso L., , Iorio F., and Vosa C.. Influence of prosthesis-patient mismatch on exercise-induced arrhythmias: afurther aspect after aortic valve replacement. . J Thorac Cardiovasc Surg . 2009 September; ;138(3): : 632– 638 .
    [Google Scholar]
  84. [84]. Unger P., , Dedobbeleer C., , Van Camp G., , Plein D., , Cosyns B., and Lancellotti P.. Mitral regurgitation in patients with aortic stenosis undergoing valve replacement. . Heart . 2009 March 24; ;
    [Google Scholar]
  85. [85]. Dumesnil JG., , Leblanc MH., , Cartier P., , Métras J., , Desaulniers D., , Doyle D., , Lemieux M., and Raymond G. . Distinctive hemodynamic features of the Freestyle aortic bioprothesis as comparedto stented bioprosthesis. . An Thorac Surg . 1998; ;66: : S130– S133 .
    [Google Scholar]
  86. [86]. Castro LJ., , Arcidi JMJ., , Fisher AL., and Gaudiani VA.. Routine enlargement of the small aortic root: a preventive strategy to minimizemismatch. . Ann Thorac Surg . 2002; ;74: : 31– 36 .
    [Google Scholar]
  87. [87]. Eichinger WB., , Botzenhardt F., , Keithahn A., , Guenzinger R., , Bleiziffer S., , Wagner I., , Bauernschmitt R., and Lange R.. Exercise hemodynamics of bovine versus porcine bioprostheses: A prospectiverandomized comparison of the mosaic and perimount aortic valves. . J ThoracCardiovasc Surg . 2005 May; ;129(5): : 1056– 1063 .
    [Google Scholar]
  88. [88]. Botzenhardt . . The Carpentier-Edwards PERIMOUNT Magna pericardial aortic bioprosthesisoffers superior hemodynamics size for size as compared to the standardCarpentier-Edwards PERIMOUNT valve. . Edwards Life Science . 2007; ;
    [Google Scholar]
  89. [89]. Walther T., , Lehmann S., , Falk V., , Metz S., , Doll N., , Rastan A., , Viehweg M., , Richter M., , Gummert J., and Mohr FW.. Prospectively randomized evaluation of stented xenograft hemodynamic function inthe aortic position. . Circulation . 2004 September 14; ;110(11 Suppl 1): : II74– II78 .
    [Google Scholar]
  90. [90]. Dalmau MJ., , Gonzalez-Santos JM., , Lopez-Rodriguez J., , Bueno M., and Arribas A.. The Carpentier-Edwards Perimount Magna aortic xenograft: a new design withan improved hemodynamic performance. . Interact Cardiovasc Thorac Surg . 2006 June; ;5(3): : 263– 267 .
    [Google Scholar]
  91. [91]. Dalmau MJ., , Gonzalez-Santos JM., , Lopez-Rodriguez J., , Bueno M., , Arribas A., and Nieto F.. One year hemodynamic performance of the Perimount Magna pericardial xenograftand the Medtronic Mosaic bioprosthesis in the aortic position: a prospectiverandomized study. . ICVTS . 2007 June; ;6(3): : 345– 349 .
    [Google Scholar]
  92. [92]. Perez de Arenaza D., , Lees B., , Flather M., , Nugara F., , Husebye T., , Jasinski M., , Cisowski M., , Khan M., , Henein M., , Gaer J., , Guvendik L., , Bochenek A., , Wos S., , Lie M., , Van NG., , Pennell D., and Pepper J.. Randomized comparison of stentless versus stented valves for aortic stenosis:effects on left ventricular mass. . Circulation . 2005 October 25; ;112(17): : 2696– 2702 .
    [Google Scholar]
  93. [93]. Kunadian B., , Vijayalakshmi K., , Thornley AR., , de Belder MA., , Hunter S., , Kendall S., , Graham R., , Stewart M., , Thambyrajah J., and Dunning J.. Meta-analysis of valve hemodynamics and left ventricular mass regression forstentless versus stented aortic valves. . Ann Thorac Surg . 2007 July; ;84(1): : 73– 78 .
    [Google Scholar]
  94. [94]. Borger MA., , Nette AF., , Maganti M., and Feindel CM. . Carpentier-Edwards Perimount Magna valve versus Medtronic Hancock II: amatched hemodynamic comparison. . Ann Thorac Surg . 2007 June; ;83(6): : 2054– 2058 .
    [Google Scholar]
  95. [95]. Laforest I., , Dumesnil JG., , Briand M., , Cartier PC., and Pibarot P. . Hemodynamic performance at rest and during exercise after aortic valvereplacement: Comparison of pulmonary autografts versus aortic homografts. . Circulation . 2002 September 24; ;106(12 Suppl I): : I-57– I-62 .
    [Google Scholar]
  96. [96]. El Hamamsy I., , Eryigit Z., , Stevens LM., , Sarang Z., , George R., , Clark L., , Melina G., , Takkenberg JJ., and Yacoub MH.. Long-term outcomes after autograft versus homograft aortic root replacementin adults with aortic valve disease: a randomised controlled trial. . Lancet . 2010 August 14; ;376(9740): : 524– 531 .
    [Google Scholar]
  97. [97]. Kulik A., , Al Saigh M., , Chan V., , Masters RG., , Bedard P., , Lam BK., , Rubens FD., , Hendry PJ., , Mesana TG., and Ruel M.. Enlargement of the small aortic root during aortic valve replacement: is there abenefit?. . Ann Thorac Surg . 2008 January; ;85(1): : 94– 100 .
    [Google Scholar]
  98. [98]. Peterson MD., , Borger MA., , Feindel CM., and David TE.. Aortic annular enlargement during aortic valve replacement: improving results withtime. . Ann Thorac Surg . 2007 June; ;83(6): : 2044– 2049 .
    [Google Scholar]
  99. [99]. Zhong Q., , Xiao Y., , Chen J., and Ma R.. Strategy of aortic root enlargement in patients undergoing aortic and mitral valvereplacement. . Ann Thorac Surg . 2010 September; ;90(3): : 782– 787 .
    [Google Scholar]
  100. [100]. Feindel CM.. COUNTERPOINT: Aortic valve replacement: size does matter. . J ThoracCardiovasc Surg . 2009 February; ;137(2): : 284– 285 .
    [Google Scholar]
  101. [101]. Yoshikawa K., , Fukunaga S., , Arinaga K., , Hori H., , Nakamura E., , Ueda T., , Tayama E., and Aoyagi S.. Long-term results of aortic valve replacement with a small St. Jude Medicalvalve in Japanese patients. . Ann Thorac Surg . 2008 April; ;85(4): : 1303– 1308 .
    [Google Scholar]
  102. [102]. Hashimoto K.. Patient-prosthesis mismatch: the Japanese experience. . Ann Thorac CardiovascSurg . 2006 June; ;12(3): : 159– 165 .
    [Google Scholar]
  103. [103]. Dumesnil JG., and Pibarot P.. Invited commentary. . Ann Thorac Surg . 2008 December; ;86(6): : 1789– 1790 .
    [Google Scholar]
  104. [104]. Pibarot P., and Dumesnil JG.. Prosthetic heart valves: Selection of the optimal prosthesis and long-termmanagement. . Circulation . 2009; ;119(7): : 1034– 1048 .
    [Google Scholar]
  105. [105]. Pibarot P., and Dumesnil JG.. Patient-prosthesis mismatch and the predictive use of indexed effective orifice area:Is it relevant?. . Cardiac Surgery today . 2003; ;1(2): : 43– 51 .
    [Google Scholar]
  106. [106]. Dellgren G., , Eriksson MJ., , Brodin LA., and Radegran K.. Eleven years’ experience with the Biocor stentless aortic bioprosthesis: clinical andhemodynamic follow-up with long-term relative survival rate. . Eur J CardiothoracSurg . 2002 December; ;22(6): : 912– 921 .
    [Google Scholar]
  107. [107]. Garcia-Bengochea J., , Sierra J., , Gonzalez-Juanatey JR., , Rubio J., , Vega M., , Fernandez AL., and Sanchez D.. Left ventricular mass regression after aortic valve replacement with the newMitroflow 12A pericardial bioprosthesis. . J Heart Valve Dis . 2006 May; ;15(3): : 446– 451 .
    [Google Scholar]
  108. [108]. Koertke H., , Seifert D., , Drewek-Platena S., and Koerfer R.. Hemodynamic performance of the Medtronic ADVANTAGE prosthetic heart valvein the aortic position: echocardiographic evaluation at one year. . J Heart Valve Dis . 2003 May; ;12(3): : 348– 353 .
    [Google Scholar]
  109. [109]. Pibarot P., and Dumesnil JG. . Prosthesis-patient mismatch: definition, clinical impact, and prevention. . Heart . 2006 August; ;92(8): : 1022– 1029 .
    [Google Scholar]
  110. [110]. Eichinger WB., , Botzenhardt F., , Gunzinger R., , Kemkes BM., , Sosnowski A., , Maiza D., , Coto EO., and Bleese N.. European experience with the Mosaic bioprosthesis. . J Thorac Cardiovasc Surg . 2002 August; ;124(2): : 333– 339 .
    [Google Scholar]
  111. [111]. Bakhtiary F., , Schiemann M., , Dzemali O., , Selami D., , Schächinger V., , Ackermann H., , Moritz A., and Kleine P.. Impact of patient-prosthesis mismatch and aortic valve design on coronary flowreserve after aortic valve replacement. . J Am Coll Cardiol . 2007; ;49(7): : 790– 796 .
    [Google Scholar]
http://instance.metastore.ingenta.com/content/journals/10.5339/ahcsps.2011.7
Loading
/content/journals/10.5339/ahcsps.2011.7
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error