1887

Abstract

Introduction: Mild Brain Injury or concussion is frequently observed during contact sports such as football and soccer. If it remains undetected, a repeat concussion can lead to long term consequences because of the vulnerable brain tissue damage. Balance Error Scoring System (BESS) test is a widely used test to detect concussion. It requires the athlete with suspected concussion to maintain his/her position in three different stances, that are, both legs, single leg and tandem, and has a total score ranging from 0 to 30. The recommended way of performing this test is to do it barefoot in clinical or semi-clinical settings. Such conditions are however difficult to achieve during an ongoing match, and athletes would like to be near the field with their cleats on - situations often found on soccer fields in eastern countries. Objective: Therefore, we aimed to assess the reliability of BESS test in different field conditions. This research is in line with Qatar National Research Strategy 2012 pillars, H.E.1.9 (prevention of brain Injury) and H.E 1.10 (control of sports injuries). Methods: This study was conducted under the auspices of McGill Sports Emergency Medicine Clinic. Athletes from soccer and football teams were approached on the field during practice games. After informed consents, they performed BESS test in three conditions, that were, barefoot, on turf with cleats and on hard surface with cleats. Each athlete was rated by three observers independently of each other. We computed mean difference in total BESS scores with 95% confidence intervals (95%CI). Comparison of total BESS scores under different conditions as well as inter-observer reliability was assessed using intraclass correlation coefficient (ICC).. Results: We recruited 49 athletes from football (n=39) and soccer (n=10) teams in this study. Thirty nine of them were male, 10 were females. Average age was 21.1 years (standard deviation [SD]=1.9). We found that total BESS scores were significantly different (P<0.001) between barefoot and the two conditions with cleats-on: 2.2 (95%CI=1.6, 2.8) for turf and 2.0 (95%CI=1.4, 2.6) for hard surface. Concordances of barefoot with turf (ICC=0.47, P=0.02) and hard surface (ICC=0.51, P=0.01) conditions were moderate. A moderate to high inter-observer reliability (0.60≥ICC≤0.75) was observed for BESS test under three conditions. Conclusion: These findings show that BESS test has a fair reliability under different conditions, and may be useful in screening concussion on the field. However, cut-off of BESS should be reduced by 1 to 2 points if it is applied on the field with cleats.

Loading

Article metrics loading...

/content/papers/10.5339/qfarf.2013.BIOP-0143
2013-11-20
2024-03-29
Loading full text...

Full text loading...

http://instance.metastore.ingenta.com/content/papers/10.5339/qfarf.2013.BIOP-0143
Loading
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error