Abstract

The temporary pacemaker (TPM) insertion must be done in symptomatic bradycardia to provide adequate heart rate and stable hemodynamic. Transvenous TPM is inserted under fluoroscopy guidance. However, in an extraordinary situation, such as the unavailability of the catheterization laboratory, transvenous TPM insertion can be performed using the blind approach. This case report focused on the procedural aspects of blind transvenous TPM insertion using femoral vein access when fluoroscopy is unavailable. By performing the blind transvenous TPM insertion, the patient should be stabilized as soon as possible. The confirmation of the lead placement using fluoroscopy was needed to ensure that the tip of the electrode was in the proper position.

Loading

Article metrics loading...

/content/journals/10.5339/jemtac.2021.12
2021-09-29
2024-03-28
Loading full text...

Full text loading...

/deliver/fulltext/jemtac/2021/3/jemtac.2021.12.html?itemId=/content/journals/10.5339/jemtac.2021.12&mimeType=html&fmt=ahah

References

  1. Kusumoto FM, Schoenfeld MH, Barrett C, et al., 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society. Circulation. 2019; 140:(8):e382–e482.   doi:10.1161/CIR.0000000000000628 .
    [Google Scholar]
  2. Brignole M, Auricchio A, Baron-Esquivias G, et al., 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace. 2013; 15:(8):1070–1118.   doi:10.1093/europace/eut206 .
    [Google Scholar]
  3. Harrigan RA, Chan TC, Moonblatt S, Vilke GM, Ufberg JW. Temporary transvenous pacemaker placement in the Emergency Department. J Emerg Med. 2007; 32:(1):105–111.   doi:10.1016/j.jemermed.2006.05.037 .
    [Google Scholar]
  4. Hensley N, Cheng A, Shah A, Hogue CW, Rozner MA. Cardiac Electrophysiology. In: Kaplan's Essentials of Cardiac Anesthesia . Elsevier;. 2018:;:40–60.   doi:10.1016/B978-0-323-49798-5.00003-6 .
    [Google Scholar]
  5. Blanco P. Temporary transvenous pacing guided by the combined use of ultrasound and intracavitary electrocardiography: a feasible and safe technique. Ultrasound J. 2019; 11:(1):8.   doi:10.1186/s13089-019-0122-y .
    [Google Scholar]
  6. Gammage MD. Electrophysiology: Temporary Cardiac Pacing. Heart. 2000; 83:(6):715-720.   doi:10.1136/heart.83.6.715 .
    [Google Scholar]
  7. Bektas F, Soyuncu S. The efficacy of transcutaneous cardiac pacing in ED. Am J Emerg Med. 2016; 34:(11):2090–2093.   doi:10.1016/j.ajem.2016.07.022 .
    [Google Scholar]
  8. Sovari AA, Zarghamravanbakhsh P, Shehata M. Temporary Cardiac Pacing. In: Cardiac Intensive Care . Elsevier;. 2019:;:456–460.   doi:10.1016/B978-0-323-52993-8.00043-6 .
    [Google Scholar]
  9. Timsit J-F. What is the best site for central venous catheter insertion in critically ill patients? Crit Care. 2003; 7:(6):397–399.   doi:10.1186/cc2179 .
    [Google Scholar]
  10. Tjong FVY, de Ruijter UW, Beurskens NEG, Knops RE. A comprehensive scoping review on transvenous temporary pacing therapy. Neth Heart J. 2019; 27:(10):462–473.   doi:10.1007/s12471-019-01307-x .
    [Google Scholar]
  11. Chun KJ, Gwag HB, Hwang JK, et al., Is transjugular insertion of a temporary pacemaker a safe and effective approach? Widmer J, ed. PLOS ONE. 2020; 15:(5):e0233129.   doi:10.1371/journal.pone.0233129 .
    [Google Scholar]
  12. Sullivan BL, Bartels K, Hamilton N. Insertion and Management of Temporary Pacemakers. Semin Cardiothorac Vasc Anesth. 2016; 20:(1):52–62.   doi:10.1177/1089253215584923 .
    [Google Scholar]
  13. Sjaus A, Fayad A. The Use of Subcostal Echocardiographic Views to Guide the Insertion of a Right Ventricular Temporary Transvenous Pacemaker—Description of the Technique. J Cardiothorac Vasc Anesth. 2019; 33:(10):2797–2803.   doi:10.1053/j.jvca.2019.01.033 .
    [Google Scholar]
  14. Pinneri F, Frea S, Najd K, et al., Echocardiography-guided versus fluoroscopy-guided temporary pacing in the emergency setting: an observational study. J Cardiovasc Med. 2013; 14:(3):242–246.   doi:10.2459/JCM.0b013e32834eecbf .
    [Google Scholar]
  15. Lanzman RS, Winter J, Blondin D, et al., Where Does It Lead? Imaging Features of Cardiovascular Implantable Electronic Devices on Chest Radiograph and CT. Korean J Radiol. 2011; 12:(5):611–619.   doi:10.3348/kjr.2011.12.5.611 .
    [Google Scholar]
http://instance.metastore.ingenta.com/content/journals/10.5339/jemtac.2021.12
Loading
/content/journals/10.5339/jemtac.2021.12
Loading

Data & Media loading...

  • Article Type: Case Report
Keyword(s): blind insertionfemoral vein accesstemporary pacemaker and transvenous pacing
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error