1887
Volume 2015, Issue 3
  • ISSN: 2305-7823
  • E-ISSN:

ملخص

Given the increasing numbers of cardiac device implantations worldwide, it is important to determine whether permanent endocardial leads across the tricuspid valve can promote tricuspid regurgitation (TR). Virtually all current data is retrospective, and indicates a signal of TR being increased after permanent lead implantation. However, the precise incidence of moderate or greater TR post-procedure, the exact mechanisms (mechanical, traumatic, functional), and the hemodynamic burden and clinical effects of this putative increase in TR, remain uncertain. We have therefore designed a multicenter, international, prospective study of 300 consecutive patients (recruitment completed, baseline data presented) who will undergo echocardiography and clinical assessment prior to, and at 1-year post device insertion. This prospective study will help determine whether cardiac device-associated TR is real, what are its potential mechanisms, and whether it has an important clinical impact on cardiac device patients.

Loading

جارٍ تحميل قياسات المقالة...

/content/journals/10.5339/gcsp.2015.41
٢٠١٥-١٠-١٧
٢٠٢٤-٠٥-١٨
Loading full text...

Full text loading...

/deliver/fulltext/gcsp/2015/3/gcsp.2015.41.html?itemId=/content/journals/10.5339/gcsp.2015.41&mimeType=html&fmt=ahah

References

  1. Mond HG, Proclemer A. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009–a World Society of Arrhythmia's project. Pacing Clin Electrophysiol. 2011; 34::10131027.
    [Google الباحث العلمي]
  2. Kurtz SM, Ochoa JA, Lau E, Shkolnikov Y, Pavri BB, Frisch D, Greenspon AJ. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States:1993–2006. Pacing Clin Electrophysiol. 2010; 33::705711.
    [Google الباحث العلمي]
  3. Kremers MS, Hammill SC, Berul CI, Koutras C, Curtis JS, Wang Y, Beachy J, Blum Meisnere L, Conyers del M, Reynolds MR, Heidenreich PA, Al-Khatib SM, Pina IL, Blake K, Norine Walsh M, Wilkoff BL, Shalaby A, Masoudi FA, Rumsfeld J. The National ICD Registry Report: version 2.1 including leads and pediatrics for years 2010 and 2011. Heart Rhythm. 2013; 10::e59e65.
    [Google الباحث العلمي]
  4. Paniagua D, Aldrich HR, Lieberman EH, Lamas GA, Agatston AS. Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads. Am J Cardiol. 1991; 82:, 1130-2, A9.
    [Google الباحث العلمي]
  5. De Cock CC, Vinkers N, van Campe LC, Verhorst PM, Visser CA. Long-term outcome of patients with multiple (>3) noninfected transvenous leads: a clinical and echographic study. Pacing Clin Electrophysiolog. 2000; 23::423426.
    [Google الباحث العلمي]
  6. Klutstein M, Balkin J, Butnaru A, Ilan M, Lahad A, Rosenmann D. Tricuspid incompetence following permanent pacemaker implantation. Pacing Clin Electrophysiol. 2009; 32:Suppl 1:S135S137.
    [Google الباحث العلمي]
  7. Webster G, Margossian R, Alexander ME, Cecchin F, Triedman JK, Walsh EP, Berul CI. Impact of transvenous ventricular pacing leads on tricuspid regurgitation in pediatric and congenital heart disease patients. J Interv Card Electrophysiology. 2008; 21::6568.
    [Google الباحث العلمي]
  8. Kim JB, Spevack DM, Tunick PA, Bullinga JR, Kronzon I, Chinitz LA, Reynolds HR. The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study. J Am Soc Echocardiogr. 2008; 21::284287.
    [Google الباحث العلمي]
  9. Sadreddini M, Haroun M, Buikema L, Morillo C, Ribas S, Divarakaramenon S, Connolly SJ, Nieuwlaat R, Lonn EM, Healey JS, Dokainish H. Tricuspid valve regurgitation induced by temporary or permanent endocardial lead insertion, and the impact of cardiac resynchronization therapy. Open Cardiovasc Med Journal. 2014; 8::8387.
    [Google الباحث العلمي]
  10. Al-Bawardy R, Krishnaswamy A, Rajeswaran J, Bhargava M, Wazni O, Wilkoff B, Tuzcu EM, Martin D, Thomas J, Blackstone E, Kapadia S. Tricuspid regurgitation and implantable devices. Pacing Clin Electrophysiol. 2015; 38::259266.
    [Google الباحث العلمي]
  11. Kucukarslan N, Kirilmaz A, Ulusoy E, Yokusoglu M, Gramatnikovski N, Ozal E, Tatar H. Tricuspid insufficiency does not increase early after permanent implantation of pacemaker leads. J Card Surg. 2006; 21::391394.
    [Google الباحث العلمي]
  12. Leibowitz DW, Rosenheck S, Pollak A, Geist M, Gilon D. Transvenous pacemaker leads do not worsen tricuspid regurgitation: a prospective echocardiographic study. Cardiology. 2000; 93::7477.
    [Google الباحث العلمي]
  13. Huang TY, Baba N. Cardiac pathology of transvenous pacemakers. Am Heart Journal. 1972; 83::469474.
    [Google الباحث العلمي]
  14. Chen TE, Wang CC, Chern MS, Chu JJ. Entrapment of permanent pacemaker lead as the cause of tricuspid regurgitation. Circ J. 2007; 71::11691171.
    [Google الباحث العلمي]
  15. Wen-Zong L, Liang M. Severe tricuspid valve regurgitation due to perforation by permanent pacemaker lead. J Card Surg. 2011; 26::555556.
    [Google الباحث العلمي]
  16. Mediratta A, Addetia K, Yamat M, Moss JD, Nayak HM, Burke MC, Weinert L, Maffessanti F, Jeevanandam V, Mor-Avi V, Lang RM. 3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation. JACC Cardiovasc Imaging. 2014; 7::337347.
    [Google الباحث العلمي]
  17. Alizadeh A, Sanati HR, Haji-Karimi M, Yazdi AH, Rad MA, Haghjoo M, Emkanjoo Z. Induction and aggravation of atrioventricular valve regurgitation in the course of chronic right ventricular apical pacing. Europace. 2011; 13::15871590.
    [Google الباحث العلمي]
  18. Vaturi M, Kusniec J, Shapira Y, Nevzorov R, Yedidya I, Weisenberg D, Monakier D, Strasberg B, Sagie A. Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode. Eur J Echocardiogr. 2010; 11::550553.
    [Google الباحث العلمي]
  19. Iskandar SB, Jackson A, Fahrig S, Mechleb BK, Garcia ID. Tricuspid valve malfunction and ventricular pacemaker lead: Case report and review of the literature. Echocardiography. 2006; 23::692697.
    [Google الباحث العلمي]
  20. Nath J, Foster E, Heidenreich PA. Impact of Tricuspid regurgitation on long-term survival. J Am Coll Cardiology. 2004; 43::405409.
    [Google الباحث العلمي]
  21. Al-Mohaissen MA, Chan KL. Prevalence and mechanism of tricuspid regurgitation following implantation of endocardial leads for pacemaker or cardioverter-defibrillator. J Am Soc Echocardiogr. 2012; 25::245252.
    [Google الباحث العلمي]
  22. Fazio S, Carlomagno G. The importance of tricuspid regurgitation and right ventricular overload in ICD/CRT recipients: beside the left, beyond the left. Pacing Clin Electrophysiol. 2011; 34::11811184.
    [Google الباحث العلمي]
  23. Höke U, Auger D, Thijssen J, Wolterbeek R, van der Velde ET, Holman ER, Schalij MJ, Bax JJ, Delgado V, Marsan NA. Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up. Heart. 2014; 100::960968.
    [Google الباحث العلمي]
  24. Seo Y, Ishizu T, Nakajima H, Sekiguchi Y, Watanabe S, Aonuma K. Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads. Circ J. 2008; 72::14651470.
    [Google الباحث العلمي]
  25. Nazmul MN, Cha YM, Lin G, Asirvatham SJ, Powell BD. Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation. Europace. 2013; 15::409413.
    [Google الباحث العلمي]
  26. Pfannmueller B, Hirnle G, Seeburger J, Davierwala P, Schroeter T, Borger MA, Mohr FW. Tricuspid valve repair in the presence of a permanent ventricular pacemaker lead. Eur J Cardiothorac Surg. 2011; 39::657661.
    [Google الباحث العلمي]
  27. Zoghbi WA, Enriquez-Sarano M, Foster E, Grayburn PA, Kraft CD, Levine RA, Nihoyannopoulos P, Otto CM, Quinones MA, Rakowski H, Stewart WJ, Waggoner A, Weissman NJ. Recommendations for Evaluating of the Severity of Native Valvular Regurgitation with Two-Dimensional and Doppler Echocardiography. J Am Soc of Echocardiography. 2003; 16::777802.
    [Google الباحث العلمي]
  28. Rahko PS. Prevalence of regurgitant murmurs in patients with valvular regurgitation detected by Doppler echocardiography. Ann Internal medicine. 1989; 111::466472.
    [Google الباحث العلمي]
  29. Grossman G, Stein M, Kochs M, Hoher M, Koenig W, Hombach V, Giesler M. Comparison of the proximal flow convergence method and the jet area method for the assessment of the severity of tricuspid regurgitation. Eur Heart J. 1998; 19::652659.
    [Google الباحث العلمي]
  30. Shapira Y, Porter A, Wurzel M, Vaturi Sagie A. Evaluation of tricuspid regurgitation severity: echocardiographic and clinical correlation. J Am Soc Echocardiogr. 1998; 11::652659.
    [Google الباحث العلمي]
  31. Rivera JM, Vandervoort P, Mele D, Weyman A, Thomas JD. Value of proximal regurgitant jet size in tricuspid regurgitation. Am Heart J. 1996; 131::742747.
    [Google الباحث العلمي]
  32. Tribouilloy CM, Enriquiez-Sarano M, Bailey KR, Tajik AJ, Seward JB. Quantification of tricuspid regurgitation by measuring the width of the vena contracta with Doppler color flow imaging: a clinical study. J Am Cardiol. 2000; 36::472478.
    [Google الباحث العلمي]
  33. Weiss R, Knight BP, Gold MR, Leon AR, Herre JM, Hood M, Rashtian M, Kremers M, Crozier I, Lee KL, Smith W, Burke MC. Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator. Circulation. 2013; 128::944953.
    [Google الباحث العلمي]
  34. Auricchio A, Delnoy PP, Regoli F, Seifert M, Markou T, Butter C, collaborative study group . First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system: novel endocardial left ventricular resynchronization therapy in heart failure patients. Europace. 2013; 15::11911197.
    [Google الباحث العلمي]
http://instance.metastore.ingenta.com/content/journals/10.5339/gcsp.2015.41
Loading
/content/journals/10.5339/gcsp.2015.41
Loading

جارٍ تحميل البيانات والوسائط...

  • نوع المستند: Research Article
هذه الخانة مطلوبة
يُرجى إدخال عنوان بريد إلكتروني صالح
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error